PDU & Remote Power Panel Installation and Maintenance

Floor PDUs and remote power panels carry UPS power to every rack in your white space. Allied Contractors installs, maintains and expands them without putting live IT loads at risk.

REQUEST A QUOTE →
Data center server aisle with power distribution

THE SERVICE

Power Distribution to the Rack

In most data centers, power leaves the UPS and passes through floor-mounted power distribution units (PDUs) and remote power panels (RPPs) before it reaches rack power strips. These units step down voltage, monitor current and give each rack its own protected circuit.

Allied Contractors installs new PDUs and RPPs, adds circuits and whips for new racks, balances loads across phases and performs preventive maintenance and thermal inspection on existing units, all under method-of-procedure change control.

PDU and RPP work connects directly to UPS maintenance, static transfer switches and overhead busway, and is part of our mission critical electrical services.

WHAT WE DO

PDU and RPP Services

New PDU and RPP Installation

Setting, feeding and terminating new floor PDUs and RPPs for new halls, pods and expansions.

Circuit and Whip Additions

New branch circuits and whips for added racks, installed under approved change windows.

Load Balancing

Phase and circuit load readings and rebalancing so units stay within capacity and redundancy limits.

Preventive Maintenance

Inspection, cleaning, torque checks, breaker exercise and transformer inspection for PDUs.

Thermal Imaging

Infrared scans of PDU and RPP connections under load to catch hot spots.

Monitoring Integration

Branch circuit monitoring and connection to your DCIM or power monitoring system.

Data center power room

TECHNICAL CONSIDERATIONS

Working Next to Live IT Load

Most PDU work happens in energized white space, so planning matters as much as the installation.

  • A and B power paths and keeping redundancy during work
  • Approved method of procedure (MOP) and change windows
  • Branch circuit capacity and the 80 percent rule
  • Phase balance across PDUs and UPS modules
  • Arc flash labeling and NFPA 70E boundaries
  • Labeling and as-built updates for every new circuit

PLANNING THE WORK

How PDU and RPP Work Is Planned

We coordinate every step with your facilities and IT teams.

Survey

Record loads, available breakers, panel schedules and rack locations.

Write the MOP

Document steps, rollback, risks and the change window for approval.

Install and Verify

Perform the work, test, label and update panel schedules and drawings.

WHERE WE WORK

Where We Work

Enterprise data centers, colocation halls, edge sites, server rooms in hospitals and plants, and network closets in commercial buildings.

We support data centers in Houston and Dallas–Fort Worth, plus Austin and San Antonio.

Technician working at a data center rack

WHY ALLIED CONTRACTORS

Licensed, Safety-Qualified Texas Electricians

Allied Contractors, LLC is a Texas commercial and industrial electrical contractor founded in 2019, with offices in Pasadena (Greater Houston), Dallas and Schulenburg and crews serving Houston, Dallas–Fort Worth, Austin and San Antonio.

  • Texas Electrical Contractor License TECL 34231
  • EMR 0.90
  • ISNetworld · Avetta · Veriforce
  • OSHA 10/30 and NFPA 70E trained crews

FREQUENTLY ASKED QUESTIONS

PDU and RPP Questions

What is the difference between a PDU and an RPP?

A floor PDU usually contains a transformer that steps voltage down and feeds several panels. A remote power panel is a smaller panelboard cabinet placed closer to the racks, fed from a PDU, that provides branch circuits.

Can new circuits be added without shutting down racks?

Usually yes. Circuits are added to energized panels under an approved method of procedure, with redundancy maintained on the other power path.

How often should PDUs be maintained?

Most data centers inspect and thermally scan PDUs at least annually, with deeper maintenance every few years based on condition, the manufacturer and your NFPA 70B program.

Do you balance loads across phases?

Yes. We take current readings and move circuits where needed so each PDU and UPS stays within its capacity and redundancy design.

Do you update panel schedules and drawings?

Yes. Every installation includes labeling and updated panel schedules, and we can update your single-line and as-built drawings.

LET'S DISCUSS YOUR FACILITY

Plan Your Next PDU or RPP Project

Tell us how many racks you are adding and how your power paths are designed. Allied Contractors will scope the work and the change windows.