Service Entrance SPDs
Type 1 or Type 2 SPDs at switchgear and main switchboards to stop large external surges.
ALLIED CONTRACTORS · HOUSTON & DALLAS
Lightning, utility switching and your own motors and drives send surges through your electrical system. Allied Contractors installs surge protective devices that keep those surges away from controls, drives and IT equipment.
REQUEST A QUOTE →
THE SERVICE
Gulf Coast storms make Texas one of the most lightning-active regions in the country, and utility switching and large motors create surges every day. Small, repeated surges slowly damage electronics, while large ones can destroy equipment at once.
Allied Contractors designs and installs surge protective devices (SPDs) at the service entrance, distribution panels and critical equipment, creating layers of protection. We also inspect existing SPDs, which often fail without anyone noticing.
Surge protection pairs well with power quality testing, power monitoring and protection of UPS systems and VFDs.
WHAT WE DO
Type 1 or Type 2 SPDs at switchgear and main switchboards to stop large external surges.
SPDs at panels feeding sensitive loads to limit what remains after the first layer.
Point-of-use protection for PLCs, drives, controls, IT racks and communications.
Checking status indicators, counters and connections, and replacing failed devices.
Review of grounding and bonding, which surge protection depends on to work.
Surge protection for standby power systems and transfer equipment.

TECHNICAL CONSIDERATIONS
An SPD that is undersized, badly placed or wired with long leads protects far less than its rating suggests.
PLANNING THE WORK
Many SPDs can be installed with a short outage at each panel.
Review the service, distribution, sensitive loads, grounding and any equipment failures.
Select SPD types and locations for layered protection.
Install SPDs during short outages, verify indicators and add them to your maintenance program.
WHERE WE WORK
Manufacturing plants with PLCs and drives, warehouses with automated conveyors and sorters, data centers and server rooms, hospitals and clinics, and commercial buildings with fire alarm, security and building automation systems.
We serve Houston, the Gulf Coast, Dallas–Fort Worth, Austin and San Antonio.

WHY ALLIED CONTRACTORS
Allied Contractors, LLC is a Texas commercial and industrial electrical contractor founded in 2019, with offices in Pasadena (Greater Houston), Dallas and Schulenburg and crews serving Houston, Dallas–Fort Worth, Austin and San Antonio.
FREQUENTLY ASKED QUESTIONS
A surge protective device limits voltage spikes by diverting surge current to ground, protecting equipment connected downstream.
Yes. Many UPS systems offer limited surge protection, and surges can still reach equipment that is not on the UPS. Layered SPDs protect the whole system, including the UPS itself.
Best practice is layered protection at the service entrance, at distribution panels feeding sensitive loads, and at critical equipment.
Most SPDs have status lights or alarm contacts. Many fail silently after absorbing surges, so they should be checked during routine maintenance.
Yes. SPDs divert surge energy to ground, so poor grounding and bonding reduces their effectiveness.
RELATED ELECTRICAL SERVICES
LET'S DISCUSS YOUR FACILITY
Tell us about your service, sensitive equipment and any unexplained failures. Allied Contractors will design layered surge protection for your facility.