ALLIED CONTRACTORS · HOUSTON & DALLAS

Commercial & Industrial Surge Protection Installation

Lightning, utility switching and your own motors and drives send surges through your electrical system. Allied Contractors installs surge protective devices that keep those surges away from controls, drives and IT equipment.

REQUEST A QUOTE →
Industrial switchgear with surge protection

THE SERVICE

Layered Protection From the Service to the Equipment

Gulf Coast storms make Texas one of the most lightning-active regions in the country, and utility switching and large motors create surges every day. Small, repeated surges slowly damage electronics, while large ones can destroy equipment at once.

Allied Contractors designs and installs surge protective devices (SPDs) at the service entrance, distribution panels and critical equipment, creating layers of protection. We also inspect existing SPDs, which often fail without anyone noticing.

Surge protection pairs well with power quality testing, power monitoring and protection of UPS systems and VFDs.

WHAT WE DO

Surge Protection Services

Service Entrance SPDs

Type 1 or Type 2 SPDs at switchgear and main switchboards to stop large external surges.

Distribution Panel SPDs

SPDs at panels feeding sensitive loads to limit what remains after the first layer.

Equipment Protection

Point-of-use protection for PLCs, drives, controls, IT racks and communications.

SPD Inspection

Checking status indicators, counters and connections, and replacing failed devices.

Grounding Review

Review of grounding and bonding, which surge protection depends on to work.

Generator and ATS Protection

Surge protection for standby power systems and transfer equipment.

Electrician testing an industrial breaker panel

TECHNICAL CONSIDERATIONS

Getting Surge Protection Right

An SPD that is undersized, badly placed or wired with long leads protects far less than its rating suggests.

  • SPD type and location under the NEC and UL 1449
  • Short conductor leads and the correct breaker or disconnect
  • Voltage protection ratings matched to the equipment
  • Surge current ratings for exposed service entrances
  • Grounding and bonding quality
  • Status monitoring and alarm contacts

PLANNING THE WORK

How a Surge Protection Project Is Planned

Many SPDs can be installed with a short outage at each panel.

Survey

Review the service, distribution, sensitive loads, grounding and any equipment failures.

Design

Select SPD types and locations for layered protection.

Install and Verify

Install SPDs during short outages, verify indicators and add them to your maintenance program.

WHERE WE WORK

Facilities That Need Surge Protection

Manufacturing plants with PLCs and drives, warehouses with automated conveyors and sorters, data centers and server rooms, hospitals and clinics, and commercial buildings with fire alarm, security and building automation systems.

We serve Houston, the Gulf Coast, Dallas–Fort Worth, Austin and San Antonio.

Commercial power distribution panel installation

WHY ALLIED CONTRACTORS

Licensed, Safety-Qualified Texas Electricians

Allied Contractors, LLC is a Texas commercial and industrial electrical contractor founded in 2019, with offices in Pasadena (Greater Houston), Dallas and Schulenburg and crews serving Houston, Dallas–Fort Worth, Austin and San Antonio.

  • Texas Electrical Contractor License TECL 34231
  • EMR 0.90
  • ISNetworld · Avetta · Veriforce
  • OSHA 10/30 and NFPA 70E trained crews

FREQUENTLY ASKED QUESTIONS

Surge Protection Questions

What is a surge protective device?

A surge protective device limits voltage spikes by diverting surge current to ground, protecting equipment connected downstream.

Do I need surge protection if I have a UPS?

Yes. Many UPS systems offer limited surge protection, and surges can still reach equipment that is not on the UPS. Layered SPDs protect the whole system, including the UPS itself.

Where should surge protectors be installed?

Best practice is layered protection at the service entrance, at distribution panels feeding sensitive loads, and at critical equipment.

How do I know if an SPD has failed?

Most SPDs have status lights or alarm contacts. Many fail silently after absorbing surges, so they should be checked during routine maintenance.

Does surge protection need good grounding?

Yes. SPDs divert surge energy to ground, so poor grounding and bonding reduces their effectiveness.

LET'S DISCUSS YOUR FACILITY

Protect Your Equipment From Surges

Tell us about your service, sensitive equipment and any unexplained failures. Allied Contractors will design layered surge protection for your facility.